Static Analysis as per IS1893 2002 :Calculation of Design Seismic Force in STAAD Pro v8i
OnlineCivilDigital
0:00 / 0:00
Static Analysis as per IS1893 2002 :Calculation of Design Seismic Force in STAAD Pro v8i
109 879 просмотров · 13 л. назад
OnlineCivilDigital
12,2 тыс. подписчиков
109 879 просмотров · 13 л. назад
Static Analysis Method & Calculation of Design Seismic Force in STAAD Pro v8i as per IS1983 - 2002
For queries: Admin@civildigital. Com
Download Staad (.std) File
http://civildigital.com/static-seismi...
Watch Here
http://civildigital.com/?p=1711
Download File
Advanced Analysis in Staad Pro v8i
Structure:
A four-story reinforced concrete office building
The building is located in Assam (seismic zone V).
The soil conditions are medium stiff
Entire building is supported on a raft foundation.
R. C. frames are infilled with brick-masonry.
Lumped weight due to dead loads is 12kN/m2 on floors and 10 kN/m2 on the roof.
Live load of 4 kN/m2 on floors and 1.5 kN/m2 on the roof.
Design Parameters:
For seismic zone V
Zone factor Z = 0.36 (Table 2 of IS: 1893)
For office building, the importance factor, I, = 1.0 (Table 6 of IS: 1893).
Building provided with moment resisting frames detailed as per IS:13920-1993.
Response reduction factor, R, = 5. (Table 7 of IS: 1893 Part 1)
Seismic Weights in Staad Pro, Fundamental Period in Staad Pro, Force Distribution with Building Height in Staad Pro, Load Combinations for Seismic Analysis as per IS1893 2002 in Staad