Fix Hot Water Tank Vapor Lockout FLAMMABLE VAPOR SENSOR LOCKOUT | HOT WATER TANK (TEMP FIX)
Wild & Wandering
0:00 / 0:00
Fix Hot Water Tank Vapor Lockout FLAMMABLE VAPOR SENSOR LOCKOUT | HOT WATER TANK (TEMP FIX)
19 784 просмотра · 6 лет назад
Wild & Wandering
491 подписчик
19 784 просмотра · 6 лет назад
This is a Temporary Fix If Your Hot Water Tank Has The 7 Flash Flammable Vapor Sensor Lockout Code.
All You Need Is
1. Check All Your Gas Lines With Soapy Water For Any Leaks.
2. Make Sure You Have Removed ANY & ALL (Paints, Paint Thinner, Gas, Rocket Fuel Ect.)
3.Turn Your Temperature Control Module OFF. Unplug or Turn Main Power Off If You Want To Be 1000% Sure It's Off.
4. Find and Remove Faulty FVS aka The Sniffer and Unhook The 2 Connectors From The Sensor.
5. Hook your Multi-meter up to the same 2 connectors.
6.Turn Multi Meter to 20K.
7. Hook All Power Back Up.
8. Turn Your Temperature Control Knob to LOW OR LIGHT.
9. Turn On The On/Off Switch to The ON Position.
10. LOOK AT YOUR MULTIMETER IF IT HAS A (1) AND NOT A BUNCH OF NUMBERS LIKE I EXPLAINED IN VIDEO THEN SWITCH THE MULTI METER PRONGS AND WIRES FROM SENSOR CABLE OPPOSITE TO WHAT THEY ARE NOW. -
11. If Your Unit Is Not Making The Clicking Noise As if It's About To Lite Then Turn Off Switch, Wait 5 minutes, Turn Back ON.
12. Turn Temperature Control Knobs From Very Hot Back To The Low/Light Setting Wait a Few Seconds And It Will Light.
13. Read Up On You Water Temps, if your Not Sure Don't Go Higher Than The Hot Setting.
14. I Don't Recommend Leaving Like This All Night, Take Your Shower And Turn Back Off When Your Done.
For Me, I've Had it Hooked Up For About 3 Days Stright, I've been Monitoring it and it's doing fine. The one Technician I called said they bypass them on newer homes. I Don't recommend but we will see what the new one does. I'll post a new Video When I hook Up New Sensor..
Thanks, and Please Like and Subscribe.. Im New and Need 1000 Subscribers.. Thanks Again..