DRY Penetrate Test or D.P.Test IN हिन्दी
Class Room DaDa
0:00 / 0:00
DRY Penetrate Test or D.P.Test IN हिन्दी
2 630 просмотров · 7 лет назад
Class Room DaDa
33,1 тыс. подписчиков
2 630 просмотров · 7 лет назад
Details of N.D.Test / Dry Penetrate Test used in different product and see the defect and test method.
Dye Penetrant Test (DPT) is also known as Liquid Penetrant Inspection (LPI) or Penetrant Test (PT). It is one of the most widely used Non Destructive Test (NDT) methods. It can be used to inspect almost all non-porous materials such as metals, plastics, ceramics etc.by this test method.
There are six basic steps to follow when using the dye penetrant solvent removable method.
1.Pre-clean part. This can range from grinding and wire brushing to merely wiping the part with a rag moistened with the cleaner/ remover.
2.Apply penetrant.
3.Remove penetrant.
4.Apply developer.
5.Evaluate indications.
6.Post-clean part.