How to Configuration Schneider Altivar Machine ATV320 VFD Setting #schneider #electrical #vfd #video

Power Plant Info.🏭🏭

0:00 / 0:00

How to Configuration Schneider Altivar Machine ATV320 VFD Setting #schneider #electrical #vfd #video

159 просмотров · 9 месяцев назад
Power Plant Info.🏭🏭
4,36 тыс. подписчиков
159 просмотров · 9 месяцев назад
Configuring a Schneider Altivar 320 VFD involves accessing the CONF menu, setting motor parameters (power, voltage, etc.), defining start/stop (two or three-wire), and setting speed references (potentiometer, analog input, or keypad). Key steps include setting the CTL menu for command (TER for terminals) and reference sources (e.g., AI3 for 4-20mA) and performing an autotune (in the SIN menu) for accurate motor performance. Always check safety guidelines and match drive settings to the motor's nameplate. Basic Setup Steps Access Configuration: From the main display (RDY), press Enter, scroll to CONF, and press Enter. Motor Parameters (SIN Menu): Go to FUSte-SIN and input motor details (Power, Voltage, Current, Freq, Speed) from the motor's nameplate. Control Mode (CTL Menu): Navigate to CTL (Command Menu). Set CHCF to SEP (Separate Ref/Cmd) for terminal control. Set CD1 (Command Input) to TER (Terminals) for start/stop via physical inputs. Speed Reference (CTL Menu): Set FR1 (Freq Ref 1) to your desired source (e.g., AI3 for analog input). For analog input scaling (e.g., 4-20mA), go to the I/O menu, select AI3-, and set CRL3 (min) and CRH3 (max). 2/3 Wire Control: In I/O - TCC, set to 2C (2-wire) or 3C (3-wire). Autotune (SIN Menu): Go to SIN - Tune. Set TUNE to YES and press Enter to start; wait for motor noise. Check status for "done" or "measure". Acceleration/Deceleration: Adjust ACC (Accel) and DEC (Decel) times in the CTL menu. Key Parameters to Know CONF: Main Configuration Menu. SIN: Simply Start Menu (Motor data, Autotune). CTL: Control Menu (Command/Ref sources, Accel/Decel). I/O: Inputs/Outputs Menu (Terminal functions, Analog scaling). CHCF: Command/Freq Channel (SEP for separate control). CD1: Command Active Channel (TER for terminals). FR1: Frequency Reference 1 (e.g., AI3). Tips Press & Hold Enter: Hold Enter for ~3 seconds to save parameter changes. Safety: Always follow local safety codes and disconnect power when wiring. Check Motor Nameplate: Match motor specs (kW, V, A, Hz) to parameters for accurate performance #life #like #automobile #machine #tecnician #chp #conveyorbelt #electrical #electricmotor . #schneider #motor #tecnician #technology #tech #commissioner #powerplant #vfd #settings #shortvideos #viral #viralvideo #video #viralshorts #viralshort #vlog #viralvideos #youtubeshorts #youtube ▶️