Перейти к содержимому

Fault E160 on Potterton / Baxi / Main boiler / How to replace Fan Assembly step by step

B Heating Service

0:00 / 0:00

Fault E160 on Potterton / Baxi / Main boiler / How to replace Fan Assembly step by step

14 442 просмотра · 2 г. назад
B Heating Service
1,06 тыс. подписчиков
14 442 просмотра · 2 г. назад
This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Fan is faulty because the fan have 220V but is not comming on. 1. Download manual https://www.wolseley.co.uk/wcsstore/E... 2. Turn off the power 3. Isolate the gas valve 4. Remove front cover 5. Remove the screws and undo the gas connection nut 6. Remove the cables and the sensing pipe (rubber tube) 7. Remove the fan 8. Replace the washers and be carful to reinsert the injector 9. Fit the fan 10. Reassemble in reverse order, ensuring that the injector is in place and the sensing pipe is connected to the fan.