Перейти к содержимому

Invt chf100a IGBT GATE VOLTAGES CHECKING || P.OFF FAULT || igbt change

S E TECH

0:00 / 0:00

Invt chf100a IGBT GATE VOLTAGES CHECKING || P.OFF FAULT || igbt change

29 975 просмотров · 3 года назад
S E TECH
6,64 тыс. подписчиков
29 975 просмотров · 3 года назад
Invt chf100a igbt gate voltages checking P.Off fault Igbt changes In this video, I discuss the repair of an inverter from invt that was experiencing a P.off error and had a shorted IGBT. The issue was caused by water entering the unit, which cut the lines and affected the voltage generation. I explain the troubleshooting process, including checking the resistor values and voltages at various points, and demonstrate the steps taken to fix the problem. The goal is to provide a detailed guide on resolving this type of issue, as there are not many such videos available on YouTube. #inverter #IGBTrepair #PFerror #waterDamage #voltageIssues