Перейти к содержимому

Hotpoint 10kg - Bed & Bath 60c Steam (Complete fail)

Mrlaundry101

0:00 / 0:00

Hotpoint 10kg - Bed & Bath 60c Steam (Complete fail)

9 892 просмотра · 6 лет назад
Mrlaundry101
27,1 тыс. подписчиков
9 892 просмотра · 6 лет назад
Don't forget to hit that subscribe button and that bell too :) I think this shows where indesit are continuing to go... At first I thought this machine was the "better version of the whirlpool", turns out that was very wrong. Washing a ¾ load of single bedding and a couple of towels with 100ml almat bio powder. Notice how no emergency rinses are performed, at the end of the cycle the towels remain dripping wet... Steam hygiene always boils the clothes as it doesn't spin first. So good luck to anyone who owns these as you can select steam on delicates etc... Note: They want £559 for the top model activecare with the same programming... take that as you wish. Note: The pump and drain system is completely clear and free of blockages, I thought this was the issue when I first got this machine but nope. Note: These time stamps will be incorrect during premier 0:00 Start of wash 3:06 Sensing start 8:42 Heat and main wash 57:23 Wash drain (Feels like 40c lmao) 58:22 Filling for steam hygiene 58:57 Tumbling start (Boil) 1:22:27 Cooling 1:22:57 Drain 1:23:30 Load fluffing 1:24:08 Balancing 1:25:05 Ramp up and sudslock (Pump turns on too late) back to balancing 1:28:30 Unbalanced ramp up and sudslock (Pump turns on too late) back to balancing 1:32:15 Unbalanced ramp up and sudslock (Pump turns on too late). Cut out and abort spin 1:34:28 1st rinse 1:40:15 Drain from rinse 1:41:08 Load fluffing 1:41:45 Balancing 1:48:00 Unbalanced ramp up and sudslock (Pump turns on too late) back to balancing 1:54:40 Unbalanced ramp up and sudslock (Pump turns on too late) back to balancing 1:56:40 Unbalanced ramp up and sudslock (Pump turns on too late) back to balancing 2:02:10 Unbalanced ramp up, back to balancing 2:03:10 Unbalanced ramp up, back to balancing 2:04:30 Unbalanced ramp up and sudslock (Pump turns on too late). Cut out and abort spin 2:06:48 2nd rinse 2:12:42 Drain from rinse 2:13:38 Load fluffing 2:14:17 Balancing 2:14:57 Water detected load fluffing 2:15:34 Balancing 2:15:50 Ramp up and sudslock (Pump turns on too late) back to balancing 2:17:30 Ramp up and sudslock (Pump turns on too late). Cut out and abort spin 2:19:30 3rd (final) rinse - manually preventing softener from dosing 2:26:58 Drain from rinse - Notice the delay the pump takes to actually start pumping, this usually happens everytime the pump is activated 2:28:00 Load fluffing 2:28:38 Balancing for 1600rpm 2:30:00 Unbalanced ramp up and massive sudslock (Pump turns on too late) back to balancing 2:39:30 Very unbalanced ramp up (and slight sudslock) back to balancing 2:40:25 Why turn the pump back off? Ramp up and sudslock (Pump turns on too late) back to balancing 2:41:40 Unbalanced ramp up, back to balancing 2:44:00 Unbalanced ramp up, back to balancing 2:44:40 Self reset, normal balancing stopped and new balancing commences 2:45:10 Ramp up... Lack of pump, too much acceleration leads to sudslock final spin at around 600rpm... this does also happen with waterlocks. 2:47:30 Sudsy anti crease 2:49:10 Cycle "Complete"