RF Amplifier linearity measurements using a power-swept CW stimulus
KF7JO
0:00 / 0:00
RF Amplifier linearity measurements using a power-swept CW stimulus
347 просмотров · 5 лет назад
KF7JO
136 подписчиков
347 просмотров · 5 лет назад
In this video, I go through the progressions of measuring an amplifier with a power-stepped CW stimulus, and arrive at a solution to measure both the amplitude linearity and phase linearity of an amplifier using a power-swept CW stimulus.
Applications used:
1) SMW-K542 Baseband Power Sweep
2) FSW Spectrum mode
3) FSW I/Q Analyzer mode
4) FSW-K7 Analog Demod mode
Timeline:
0:00 Introduction
0:28 Stepped RF Level in Zero Span Spectrum Analyzer mode - limited to 1ms/power level; amplitude measurement only
2:27 Stepped Baseband Level in Zero Span Spectrum Analyzer mode - limited by RBW; amplitude measurement only
3:22 Swept Baseband Level in Zero Span Spectrum Analyzer mode - limited by RBW; amplitude measurement only
4:36 Swept Baseband Level in I/Q Analyzer mode - limited by Analysis Bandwidth; amplitude and phase linearity measurement
6:37 Drawback of I/Q Analyzer mode - requires post-processing to compensate when generator and analyzer are not frequency locked
7:04 Swept Baseband Level in Analog Demod mode - limited by Analysis Bandwidth; amplitude and phase linearity measurement, immune to frequency difference between generator and analyzer