Перейти к содержимому

How to: Load Cell Replacement and Scale Calibration Forte AP, Forte BG

Baratza

0:00 / 0:00

How to: Load Cell Replacement and Scale Calibration Forte AP, Forte BG

13 835 просмотров · 12 лет назад
Baratza
14,7 тыс. подписчиков
13 835 просмотров · 12 лет назад
This video is about Forte Series, Load Cell Replacement & Scale Calibration For additional support you can call us Monday through Friday 8AM-5PM PST or email support@baratza.com. **Please order your parts from the website as we do not do parts orders over the phone for inventory and tracking purposes. https://www.baratza.com/cgi-bin/comme... 0:00 Intro 0:29 Error Codes 0:39 Moving Arms and Removing Case 3:38 Removing the Display 5:24 Removing Old Load Cell 6:04 Orienting and Installing Load Cell 7:50 Securing Load Cell 8:30 Installing the Belt Casting 9:45 Installing Load Cell Platform 12:54 Installing Display 14:00 Installing Case 15:13 Recalibration