How is adhesive tape holding power tested at room and elevated temperatures?
YG TAPE
0:00 / 0:00
How is adhesive tape holding power tested at room and elevated temperatures?
45 просмотров · 6 дн. назад
YG TAPE
31 подписчик
45 просмотров · 6 дн. назад
This YG Group laboratory demonstration shows the complete holding power / static shear adhesion test process, including specimen conditioning, steel panel cleaning, specimen preparation, rolling, dwell time, loading, and result recording.
Test conditions shown:
• Specimen conditioning: ≥24 h
• Bonded area: 25 mm × 25 mm
• Load: 1 kg
• Dwell time: 20 min
• High-temperature test: 80°C
YG TS512-1 demonstration results:
Room temperature: ≥168 h without failure
80°C / 24 h: 1 mm displacement
Holding power indicates how well adhesive tape resists movement under sustained shear load. Results should only be compared when the test conditions are equivalent.
This demonstration references GB/T 4851-2014. Related methods include ISO 29863 and ASTM D3654/D3654M.
For tape samples, technical data, or application support, visit:
www.ygtape.com
#AdhesiveTape #HoldingPowerTest #StaticShear #TapeTesting #YGGroup