CT TESTING, CURRENT TRANSFORMER TESTING, SVERKER, CBCT, SITE TEST, CT RATIO, TAMIL, EASY UNDERSTAND
AK ELECTRIC
0:00 / 0:00
CT TESTING, CURRENT TRANSFORMER TESTING, SVERKER, CBCT, SITE TEST, CT RATIO, TAMIL, EASY UNDERSTAND
2 357 просмотров · 1 г. назад
AK ELECTRIC
7,73 тыс. подписчиков
2 357 просмотров · 1 г. назад
00:00 WELCOME
00:02 CURRENT TRANSFORMER WORKING PRINCIPLE
02:10 SVERKER RELAY TEST KIT SWITCH ON
02:45 CT PRIMARY CURRENT INJECTION
02:58 CT PRIMARY CURRENT & CT SECONDARY CURRENT MEASURING
04:29 SVERKER 750 RELAY TEST KIT CONNECTION & SWITCH ON
07:07 THANKS
HOW TO USE DISTURBANCE HANDLING TOOL IN ABB RELAY I DISTRUBANCE RECORD IN ABB RELAY I PCM600 2.11
• HOW TO USE DISTURBANCE HANDLING TOOL IN AB...
TURNS RATIO TEST | POWER TRANSFORMER RATIO TEST | SITE TEST | MEGGER TTRU3 | TAMIL | 33 TAP POSITION
• TURNS RATIO TEST | POWER TRANSFORMER RATIO...
TRANSFORMER TURNS RATIO TEST (TAMIL) THEORITICAL
• TRANSFORMER RATIO TEST - தமிழ், CIRCUIT & ...
TRANSFORMER TURNS RATIO TEST (ENGLISH) THEORITICAL
• TURNS RATIO TEST - ENGLISH, CIRCUIT DIAGRA...
BUS BAR DIFFERENTIAL TEST | 87B TEST | BUS BAR STABILITY TEST | SWITCHGEAR TEST | SITE ACTUAL TEST
• BUS BAR DIFFERENTIAL TEST | 87B TEST | BUS...
CT TESTING, CURRENT TRANSFORMER TESTING WITH CT ANALYZER, PRACTICLE TESTING, TEST REPORT MAKING EASY
• CT TESTING, CURRENT TRANSFORMER TESTING WI...
CT TESTING, MULTI RATIO CURRENT TRANSFORMER TESTING WITH CT ANALYZER & CT SB2.SITE PRACTICAL TESTING
• CT TESTING, MULTI RATIO CURRENT TRANSFORME...
ATS-AUTOMATIC TRANSFER SWITCH IN SWITCHGEAR FULL EXPLANATION, ATS SITE TEST, AUTO TRANSFER SWITCH
• ATS-AUTOMATIC TRANSFER SWITCH IN SWITCHGEA...
SWEEP FREQUENCY RESPONSE ANALYZE TEST, SFRA TEST FOR TRANSFORMER, FULL CONCEPT, TEST RESULT ANALYZE
• SWEEP FREQUENCY RESPONSE ANALYZE TEST, SFR...
VT TEST, VOLTAGE TRANSFORMER TESTING, CPC100, TEST REPORT MAKING, SITE TEST, RATIO TEST
• VT TEST, VOLTAGE TRANSFORMER TESTING, CPC1...
HOW TO CONNECT ABB REM615 RELAY WITH PCM600 I ABB REM615 ONLIINE CONFIGURATION I IP ADDRESS ENGLISH
• HOW TO CONNECT ABB REM615 RELAY WITH PCM60...
TRANSFORMER TAN DELTA TEST, POWER FACTOR TEST, FULL CONCEPT, MODES GST, UST, TYPES, PURPOSE, PART -1
• TRANSFORMER TAN DELTA TEST , POWER FACTOR ...
TRANSFORMER TAN DELTA TEST, DISSIPATION FACTOR TEST, POWER FACTOR TEST, GSTg, TEST REPORT, PART - 2
• TRANSFORMER TAN DELTA TEST, DISSIPATION FA...
TURNS RATIO TEST - ENGLISH, CIRCUIT DIAGRAM, TEST REPORT ANALYSE, FORMULA, RATIO TEST OF TRANSFORMER
• TURNS RATIO TEST - ENGLISH, CIRCUIT DIAGRA...
Dyn1 VECTOR GROUP TEST, POWER TRANSFORMER TESTING, தமிழ் ,SITE PRATICAL TEST, RESULT ANALYZE
• Dyn1 VECTOR GROUP TEST, POWER TRANSFORMER ...
TRANSFORMER MAGNETIC BALANCE TEST OR CORE BALANCE TEST தமிழ், SITE TEST, EASY UNDERSTANDING
• TRANSFORMER MAGNETIC BALANCE TEST OR CORE ...
AMMETER TESTING BY SECONDARY INJECTION, தமிழ் ,CPC 100, CT RATIO 800/5, CROMPTON AC AMMETER TESTING
• AMMETER TESTING BY SECONDARY INJECTION, தம...
ACB TESTING, AIR CIRCUIT BREAKER LONG, SHORT DELAY TRIP, INSTANTNAEOUS TRIP, GROUND FAULT, SITE TEST
• ACB TESTING, AIR CIRCUIT BREAKER LONG, SHO...
VOLTMETER TESTING BY SECONDARY INJECTION, தமிழ், SITE TEST, CPC100, VT RATIO, AC VOLTMETER TESTING
• VOLTMETER TESTING BY SECONDARY INJECTION, ...