Inspection Number: 431531-3711 Date: 10/14/2026 Time: 15:50 Technician: Ray Marin Customer Name: Timmothy Jackson Property Address: 4107 Madrona Drive SE, Port Orchard, WA 98366 Notes: Measurements (##.# ft) refer to the video’s distance counter. Each segment begins at the farthest point, and the camera records as it withdraws. Accessed through the cast iron cleanout in the basement. The line continued to 21.0 feet where it transitioned to a concrete pipe. The concrete pipe continued to 64.7 feet with an ABS (Black Plastic) segment, presumably a repair, at 53 to 57 feet. The concrete pipe has minor root intrusion at the seams throughout the line. At 34.0 feet, there is major root intrusion with 80% blockage. At 33.6 feet there is minor root intrusion at the bottom of the pipe which can trap debris. The line has a belly or low point from 30 to 39 feet. Recommendations Recommend having a qualified plumber evaluate and correct drainage to reduce buildup and blockages.