Перейти к содержимому

EST3 Programming | Cause & Effect Programming using wildcards character

Electrical and electronic innovation

0:00 / 0:00

EST3 Programming | Cause & Effect Programming using wildcards character

124 просмотра · 2 мес. назад
Electrical and electronic innovation
3,21 тыс. подписчиков
124 просмотра · 2 мес. назад
In this tutorial, we start from scratch by creating a new EST3 project, designing Cause & Effect logic, using wildcard characters to simplify programming, and finally compiling the project to check and apply the programming. A practical step-by-step guide for anyone learning EST3 fire alarm programming. 🚨 Create Project → Design Cause & Effect → Use Wildcards → Compile & Test Time codes 00:00 – Create a New Project Start by creating a new project in the programming software. This project will contain all the system configuration, devices, messages, and cause-and-effect programming. 00:03 – Name Your Project Give your project a clear and recognizable name. It is recommended to use the building name, site name, or project reference for easy identification. 00:06 – Set a Project Password Create a password that you can easily remember. This password will be required whenever you need to open or modify the project, so make sure to keep it safe. 00:11 – Enter the Panel Display Name Enter the name that will appear on the fire alarm panel display. This can be the name of the establishment, building, company, or site where the system is installed. 00:26 – Configure the Trouble Reminder The Trouble Reminder can be left at its default setting. However, depending on the project requirements, you can adjust the reminder interval. In this example, the reminder is set to 5 minutes to ensure that active trouble conditions continue to receive attention. 00:45 – Select Panel Display Options Choose the options and information you want to be displayed on the panel. Select the features that are required for your specific project and system configuration. 01:17 – Select the Cabinet Size Choose the appropriate cabinet size depending on the requirements of your project. Consider the number of cards, loops, power supplies, and possible future expansion. 01:27 – Add the Loop Card Add the required loop card, such as the SDDC1, to the system configuration. Ensure that the selected card matches the actual hardware installed in the panel. 01:46 – Add Devices to the Loop Card Add the addressable devices connected to the loop card, including smoke detectors, heat detectors, monitor modules, control modules, and other field devices. Make sure that the programmed device addresses match the physical installation. 02:47 – Configure System Messages Configure the messages that will appear on the panel when different events occur, such as Alarm, Trouble, or Supervisory conditions. Clear and descriptive messages are important because they help users and technicians quickly identify the type and location of an event. 04:39 – Designing Cause and Effect Using Wildcard Characters Learn how to design cause-and-effect logic using wildcard characters. Wildcards can simplify programming by allowing multiple devices or points with similar characteristics to be included in the same programming rule, reducing the amount of programming required. 05:57 – Design the Cause-and-Effect Logic Create the cause-and-effect programming for the system by defining what actions should occur when specific events are activated. For example, an alarm from a detector may activate notification appliances, release doors, shut down HVAC equipment, or trigger other programmed outputs depending on the system design. Always test the cause-and-effect logic after programming to ensure the system operates as intended.