4/4 CPX-AP-I-EP in Rockwell PLC via EtherNet/IP: Using functions of AOIs
Festo Service
0:00 / 0:00
4/4 CPX-AP-I-EP in Rockwell PLC via EtherNet/IP: Using functions of AOIs
1 591 просмотр · 3 года назад
Festo Service
10,1 тыс. подписчиков
1 591 просмотр · 3 года назад
The Festo tutorial is about commissioning the CPX-AP-I-EP in Rockwell PLC via EtherNet/IP. This video shows how to use the functions of the AOIs.
00:00 parts list: products and software
00:11 Application Note
00:24 CPX-AP-I-EP Parameter AOI Read and Write Function
05:08 CPX-AP-I-EP IO-Link Parameter AOI Read and Write Function
15:17 CPX-AP-I-EP Diag Functions
See Application Note
CPX-AP-I-EP Module Parameterization in Allen-Bradley PLC Through EtherNet/IP Network
https://www.festo.com/de/de/search/?t...
This video shows the instructions at the following products as an example:
Rockwell PLC, 1769-L24ER-QBFC1B, series 01
8086610, head module, CPX-AP-I-EP-M12, Rev 01
8086604, IO Link assembly, CPX-AP-I-4IOL-M12, Rev 01
Studio 5000, Version 34.00.00
Studio 5000 Logix Designer, Version 34.00.00
RSLinx Classic, Version 4.30.00 CPR 9 SR 13.0
Festo Field Device Tool, Version V2.10.5.198
Festo Service – the channel around the topic service and support. Commissioning, configuring, using and repairing the Festo products easily and quickly. The tutorials of service2see and software2see will support you!
Visit us on the Festo website:
https://www.festo.com
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Safety instructions
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
All guidelines, regulations and specifications applicable in the country in which you are located must be complied with before, during and after carrying out this work.
Only qualified specialized personnel who have undergone training and instruction are permitted to install, repair and commission the equipment; such work must be carried out in accordance with the operating instructions for the products concerned. All equipment must always be switched off before commencing maintenance and repair work. All power supplies must be permanently disconnected.
Some protective devices are taken out of operation during maintenance and repair work. They must be properly reinstalled and put back into operation immediately after the work has finished, and their correct functioning must be checked.
Prior to starting work you must read and understand the safety instructions and the instructions for handling the product in full. You must also ensure compliance with these instructions at all times whilst carrying out your work. No liability whatsoever shall be accepted for damage caused by noncompliance. Although every care has been taken when drafting these instructions, Festo SE & Co. KG does not accept any liability for any errors they may contain or the consequences of such errors. Likewise, no liability is accepted for direct or consequential damage resulting from incorrect use of the products and tools.
Compliance with the applicable regulations governing occupational safety, safety engineering and interference suppression, as well as the stipulations contained in these operating instructions, is a mandatory requirement when working with the products. The General Terms and Conditions of Festo SE & Co. KG, which can be viewed on the Festo website (www.festo.com), also apply.
Should you have any questions or concerns, please contact Festo SE & Co. KG directly. Do not start work until these questions or concerns have been clarified.
#Festo #service2see #CPX #CPX-AP-I