Mitsubishi Montero P0102 Mass Airflow Sensor Circuit
The Mitsubishi Montero Channel
0:00 / 0:00
Mitsubishi Montero P0102 Mass Airflow Sensor Circuit
3 946 просмотров · 1 год назад
The Mitsubishi Montero Channel
7,04 тыс. подписчиков
3 946 просмотров · 1 год назад
CIRCUIT OPERATION
• The volume airflow sensor power is supplied from
the MFI relay (terminal No. 1), and the ground is
provided on the PCM (terminal No. 88).
• 5-volt power is applied to the volume airflow sensor output terminal (terminal No. 3) from the PCM
(terminal No. 63). The volume airflow sensor generates a pulse signal when the output terminal
and ground are opened/closed (opened/short).
.
TECHNICAL DESCRIPTION
• While the engine is running, the volume airflow
sensor outputs a pulse signal which corresponds
to the volume of air flow.
• The PCM checks whether the frequency of this
signal output by the volume airflow sensor while
the engine is running is at or above the set value.