Перейти к содержимому

Fire Alarm System September 2026 Walk Test #firealarms

Notifier-457

0:00 / 0:00

Fire Alarm System September 2026 Walk Test #firealarms

655 просмотров · 12 дней назад
Notifier-457
2,04 тыс. подписчиков
655 просмотров · 12 дней назад
We do our walk test for the previous month of September, featuring Simplex SmartSync TrueAlert notification appliances that were used in s6 System Test 10 and the short version of it. This is also the very first video to use my new Hochiki SOE-24V, which has replaced the SLR-24v for much better performance. s6 System Test 10 is at the end screen, or you may watch it here:    • Notifier NFS2-640 s6 Fire Alarm System Tes...   Here's also the shorter version:    • New Simplex SmartSync TrueAlerts Quick Fir...   Timestamps: 00:00-00:04: Intro 00:05-00:07: Begin Walk Test 00:08-00:29: M033 (Amp Pull Station) 00:30-00:53: M028 (Right Panel Pull Station) 00:54--01:22: M026 (Annunciator Pull Station) 01:23-01:49: M023 (Front Door Pull Station) 01:50-02:12: M003 (Left Conventional Pull Station 1) 02:13-02:37: M029 (Right Conventional Pull Station 2) 02:38-03:10: M025 (Left Conventional Pull Station 2) 03:11-03:28: M030 (Right 2-Wire Smoke) (Smoke Spray) 03:29-03:52: M024 (Left 2-Wire Smoke) (Smoke Spray) 03:53-04:15: M041 (Right Conventional Pull 1) 04:16-04:37: M045 (CO Detector) 04:38-04:57: M047 (Emergency Acknowledge Switch) 04:58-05:05: M048 (Emergency Silence Switch) 05:06-05:28: M004 (Tornado Alert) 05:29-05:55: M045 (Yellow Pull Station) 05:56-06:15: M006 (Simplex Key Switch) 06:16-06:30: M005 (Lockdown Alert) 06:31-06:52: D010 (Agent Release Detector) (Magnet) 06:53-07:15: M034 (Conventional Duct Detector) (Key Switch) 07:16-07:49: D004 (Back Heat ROR) (ROR) 07:50-08:20: D006 (Right Front Heat ROR) (ROR) 08:21-08:43: M036 (Agent Release Pull Station) 08:44-08:54: M037 (Agent Release Abort Switch) 08:55-09:21: D005: (Duct Detector) (RTS) 09:22-09:40: M041 (Silent Knight Key Switch) 09:41-10:04: D001 (Left Front Smoke) (Magnet) 10:05-10:27: D003 (Corner Smoke) (Magnet) 10:28-10:54: D008 (Amp Smoke) (Magnet) 10:55-11:12: D002 (Left Front Heat) 11:13-11:38: D007 (Right Front Smoke) (Magnet) 11:39-11:57: D008 (Amp Heat) 11:58-12:08: End Walk Test 12:09-12:14: Outro This was done in a controlled environment!! Never pull fire alarms in real buildings, unless it's a real emergency, and NEVER tamper with life and safety equipment out in public, unless you have the authority to do so!! You will get into a ton of trouble with the law, face hefty fines, and possible jail time!! This video, and I, are not held responsible for your actions!! I recommend that you DO NOT watch this video if you have epilepsy to flashing strobes or lights, as this video contains them!! Keywords: Fire alarm system, alarm device, Smoke detector, Honeywell, System, Manual fire alarm activation, Fire alarm control panel, Sound, Sound Effect, Wire, notifier nfs2-640, notifier nfs-320, johnson controls ifc2-640, honeywell xls140-2, johnson controls ifc-320, honeywell xls-120, notifier onyx panel, notification appliance, addressable fire alarm panel, electronic component, light-emitting diode, fire drill, notifier digital voice command, notifier dvc, notifier voice evacuation, notifier voice evac, walk test Subscribe to My Channel:    / @notifier-457   Follow Me on Instagram:   / notifier457   Follow and Friend me on Tik-Tok:   / notifier.457   New System Request Form: https://forms.gle/CQHxanYHBrYqMKVJA #systemtest #notifier #firealarms