Перейти к содержимому

Blomberg rapidjet cottons 40 prewash and extra rinse (blankets and dressing gowns test GONE WILD!!!)

Washerboy2006

0:00 / 0:00

Blomberg rapidjet cottons 40 prewash and extra rinse (blankets and dressing gowns test GONE WILD!!!)

3 340 просмотров · 4 г. назад
Washerboy2006
5,64 тыс. подписчиков
3 340 просмотров · 4 г. назад
Finally got round to doing a test I really wanted to do with this machine the blanket and dressings gowns test! This machine put up the best fight so far it managed to get this full load completely wet in around 40 minutes (half the time it took the Samsung) and didn’t need me to manually fill it up once unlike the WTG The machine reached its top up limited on the prewash so unfortunately washed completely dry on it but it did get this load wetter than the Samsung did on its prewash Was very happy to see that even with prewash on the machine will reset the top up counter and top up on the main wash saturation if the level gets too low even with it filling to a very deep level at first The intensive action and over 1 hour long Aquatech phase made the main wash very foamy which gave perfect results unlike the Samsung that didn’t have a single bit of soap once everything was wet in it The spins are where it gets interesting I’ve never had to say this with any other wash in this machine but I wish it did 1 300rpm burst on every spin with a full load instead of just 1 burst on the first spin this resulted in chaos sudslocks thankfully the machine didn’t puke at all but did glitch after the first sudslock and got stuck filling for a sump flush while in anti suds resulting in it filling a quarter of the way up the door just to drain it all out again. good thing I ain’t on a water meter and an even better thing is that I have really low water pressure as if I didn’t there was a risk the machine could have really badly overfilled and flooded! I’m honestly just glad that the machine did that and didn’t continue to spin when it was in anti suds resulting in it flooding suds out the drawer and then completely freeze like it did previously. still think that awful excuse of a smart app aka HomeWhiz has left corrupted software on the main PCB and that’s what caused it to continue filling up 😐 The third and fourth interm spins are where it gets weird I don’t understand why on earth it cut out on the second attempt of both spins due to the tiny waterlock that was almost cleared then proceeds to completely abort the spins! Especially with the fact the machine allows 3 spin attempts for every spin and then aborts if it can’t complete the third attempt what I find even weirder is that by cutting out on the second attempt and going straight into rinse it acted like it was doing the half load glitch so was topping up VERY frequently unlike the first 2 rinses Overall it coped the best out of all the machines I’ve done this test in whether it constantly sudslocked or not do I think it could’ve been better though yes I do especially with it glitching and also it aborting 2 spins when it absolutely wasn’t necessary 0:00 Prepare the load 4:33 Begin prewash 17:45 Prewash (top up limit reached will continue to wash dry without adding any more water) 30:47 Prewash drain (full load detected and time altered) 31:37 Main wash (saturation and add main wash detergent) 45:54 Main wash (intensive action with heating and temp holding throughout) 1:49:38 Main wash (long Aquatech phase | uses jet system every 3 tumbles) 2:53:16 Main wash (cool down/anti suds) 2:55:35 Drain 2:56:35 First interm spin (300rpm spin burst with MASSIVE SUDSLOCK) 2:58:35 cut out and glitched anti suds resulting in the machine overfilling 3:04:14 First spin (2nd attempt for 1000rpm spin with MASSIVE SUDSLOCK) 3:06:00 Cut out and anti suds 3:11:06 First interm spin 3rd successful attempt 1000rpm 3:19:50 First rinse with Aquatech 3:24:17 First rinse with Aquatech (top up to deeper level) 3:27:45 First rinse with Aquatech (top up again to deep level) 3:38:58 Drain 3:40:10 Second interm spin 1000rpm (big sudsy waterlock) 3:41:53 Cut out and anti suds 3:47:00 Second interm spin 2nd successful attempt 1000rpm 3:57:23 Second rinse with Aquatech 4:02:10 Second rinse with Aquatech (top up to LOWER level? ls meant to top up deeper so don't know why it filled lower) 4:05:16 Second rinse with Aquatech (top up to deep level) 4:17:21 Drain 4:18:34 Third interm spin 1000rpm (big sudsy waterlock) 4:20:18 Cut out and anti suds 4:25:25 Third interm spin 1000rpm 2nd attempt (small waterlock) 4:32:20 Cut out (but keeps pump on?) when waterlock is almost cleared and aborts the entire spin 4:32:30 Third rinse with rinse programming changed to do frequent top ups!? 4:43:36 Drain 4:44:40 Fourth interm spin 1400rpm (big sudsy waterlock) 4:46:33 Cut out and anti suds 4:51:40 Fourth interm spin 2nd attempt (small sudsy waterlock) 4:57:01 Cuts out (with pump left on again?) when waterlock is nearly cleared and aborts entire spin 4:57:07 Final rinse with Aquatech and frequently top ups 5:17:56 Drain 5:19:13 Final spin burst 600rpm (big sudsy waterlock) 5:20:57 Cuts out and anti suds 5:26:04 Final spin burst 600rpm 2nd successful attempt 5:31:34 Final spin 1400rpm 5:41:18 Anti crease 5:42:52 Anti crease+ end and results