How to adjust zero (rerange) of your pressure transmitter FCX-All-VG ?

Fuji Electric France

0:00 / 0:00

How to adjust zero (rerange) of your pressure transmitter FCX-All-VG ?

623 просмотра · 3 года назад
Fuji Electric France
688 подписчиков
623 просмотра · 3 года назад
12 reasons you should use Fuji Electric FCX All-VG pressure transmitter : ✅ Short delivery time (Made in France) ✅ High static pressure differential: up to 1400 bar (20,300 PSI) ✅ High accuracy (up to 0.04%) and repeatability performance ✅ Very low failure rate ✅ Wide temperature range: from -70°C to 350°C ✅ High reliability and long-term stability ✅ Smart transmitter IOT: multiple communication protocol HART, Fieldbus ✅ Improved visualization and user friendly: LCD digital indicator with bar graph ✅Excellent resistance to aggressive, adhesive, crystallizing and viscous fluids ✅ Response time: 80 ms (twice as fast as FCX-AII V5) ✅ High resistance to harsh environments: ATEX, IECEx, cCSAus ✅ Predictive Maintenance: servicing function and fault detection Suitable for pressure, level, density, and flow rate measurements with linearization function Scope of applications: Chemical, Energy, Pulp & Paper, Food, Steel, Water, Hydrogen, Oil&Gas ➡️Download the Instructions manual FCX-AII-VG here : https://www.fujielectric.fr/en/system... ➡️Here more informations about the pressure transmitter FCX All-VG https://www.fujielectric.fr/en/produc... 🔔 Subscribe to our Youtube channel and you'll never miss a video :    / @fujielectricfrance   ➡️ Subscribe to our newsletter in order not to miss out on any of the latest information. https://fujielectric.us12.list-manage... 📱 Follow us on Linkedin :   / fuji-electric-france-s-a-s-   🔎Steps: Requirements: Connect the cables to the power terminals and power the transmitter with 24Vdc. Open the digital indicator cover. The manifold has 5 valves. 2 isolation valves to isolate the pressure transmitter from the process fluid. 1 balancing valve to equalize the measuring chambers. 2 test/drain valves to drain the measurement process fluid. Isolate the pressure transmitter from the process fluid by closing both isolation valves simultaneously. Balance the two pressure chambers by opening the valve to avoid any unilateral pressure that could damage the pressure sensor. Open the two vent/drain plugs on the transmitter to set the measuring chambers at atmospheric pressure. On the digital indicator, press the "Mode" key for 3 seconds to access the configuration menu. Press the "+" key several times until the "L-1: Lrv Adj" setting: Zero setting. Press the "Mode" key to enter the "L-1: Lrv Adj" menu Press the "Mode" key to accept the zero value Press the "Mode" key to show the saving menu Press the "Mode" key to save the setting Press the "+" key to get out of the "L-1: Lrv Adj" menu Press the "Mode" key for 3 seconds to get out of the setting menu Check the displayed measurement value and confirm zero value Close and tight the two vent/drain plugs on the transmitter Open the isolation valves of the fluid process simultaneously Separate the two chambers of the pressure transmitter by closing the balancing valve Open the drain valves to drain the fluid process. Beware of the risk of fluid projection. Close the drain valves. Assemble and tight the digital indicator cover.