#Urea_cancel #DEF_cancel
#P205A-11 Urea tank temperature sensor Circuit short to ground
#P205A-29 Urea tank temperature sensor Invalid signal
#P205A-22 Urea tank temperature sensor Signal range high fault
#P205A-21 Urea tank temperature sensor Signal range low fault
#P205A-2F Urea tank temperature sensor Communication error
#P203A-22 Urea DEF tank level sensor signal range high error
#P203A-21 Urea DEF tank level sensor signal range low error
#P203A-24 Measured tank level is implausible high in comparison with the dosed amount
#P203A-23 Measured tank level is implausible low in comparison with the dosed amount
#P203A-2F Signal error for CAN message for Urea Tank Temperature
#P203A-00 Urea DEF level sensor Monitoring related failure
#P205A-A3 Urea tank temperature sensor System Voltage High
#P205A-A2 Urea tank temperature sensor System Voltage Low
#P205A-24 Urea DEF tank temperature sensor Plausibility high failure
#P205A-23 Urea DEF tank temperature sensor Plausibility low failure
#U05A3-00 Urea DEF Quality sensor CAN communication failure (DLC check)
#U02A2-00 Urea DEF quality sensor CAN communication lost
#P206A-29 Concentration invalid failure mode identifier error
#P206A-92 DEF property detection error
#P206A-15 Short circuit to battery or open load error transmitted by quality sensor
#P206A-11 short circuit to ground error transmitted by quality sensor
#P206A-22 Electrical signal range maximum error transmitted by quality sensor
#P206A-21 Electrical signal range maximum error transmitted by quality sensor
#P2042-29 Temperature invalid failure mode identifier error transmitted by quality sensor
#P2042-15 Temperature short circuit to battery or open load error transmitted by quality sensor
#P2042-11 Temperature short circuit to ground error transmitted by quality sensor
#P2042-22 Temperature electrical signal range maximum error transmitted by quality sensor
#P2042-21 Temperature electrical signal range minimum error transmitted by quality sensor
#P207F-68 Urea/DEF quality Diesel contamination detected in urea tank
#P206A-92 Urea/DEF quality sensor - Property detection error
#P206A-2A Urea/DEF quality sensor-Concentration stuck−in−range error
#P20EE-00 SCR catalyst efficiency low
#P24FE-85 SCR Monitoring of the upper limit of the adaption factor
#P24FE-84 SCR Monitoring of the lower limit of the adaption factor
#P20FE-94 SCR - Additional Urea/ DEF dosing monitoring failure
#P20E9-92 Urea/ DEF over pressure detection during after run
#P06F0-64 Urea/ DEF supply module temperature sensor Signal not valid
#P20AC-31 Supply module heater temperature sensor Signal not available
#P20AC-29 Supply module heater temperature sensor Signal not valid
#P208A-38 Urea supply module Motor driver failure
#P208A-86 Urea supply module Motor driver intermittent failure (Temporary)
#P06F0-31 Urea supply module Temperature sensor signal not available
#P06F0-29 Urea supply module Temperature sensor signal invalid
#P2047-2B Urea/ DEF injector High side and low side short circuit
#P20A0-13 Urea supply module Revert valve - Open circuit
#P20A0-98 Urea supply module Revert valve - Over temperature
#P20A0-12 Urea supply module Revert valve - Short to battery
#P20A0-11 Urea supply module Revert valve - Short to ground
#P20A0-64 Urea supply module Reverting valve error
#P20A0-9A Urea supply module Reverting valve error at low ambient temperatur
#P208A-13 Urea DEF supply module Main Pump Circuit open
#P208A-4B Urea DEF supply module Main Pump Over temperature
#P208A-12 Urea DEF supply module Main Pump Circuit short to battery
#P208A-F0 Urea DEF supply module Main Pump High side short circuit to battery
#P208A-11 Urea DEF supply module Main Pump Circuit short to ground
#P05EE-F0 Urea DEF supply module Main Pump High side Overtemperature
#P208A-F1 Urea DEF supply module Main Pump High side short circuit to ground
#P208A-1F Urea supply module Motor intermittent speed deviation
#P208A-77 Urea DEF supply module Motor speed deviation
#P208A-93 Urea supply module Motor not available
#P20F5-00 Urea DEF consumption too high
#P20F4-00 Urea DEF consumption too low
#P204F-93 SCR Urea pressure buildup error
#P20E9-00 Urea DEF overpressure error
#P202D-00 Urea DEF dosing valve - Leakage detection during no dosing
#P20A0-92 SCR Urea DEF backflow line plausibility error
#P2062-94 Urea supply module Pump fails to stabilize the pressure
#P204F-94 SCR Urea pressure drop monitoring error
#P2047-92 Urea dozer deviates more from the desired value