Перейти к содержимому

Zeiss LSM800 Airyscan confocal tutorial

Bioimaging Unit

0:00 / 0:00

Zeiss LSM800 Airyscan confocal tutorial

23 412 просмотров · 5 лет назад
Bioimaging Unit
705 подписчиков
23 412 просмотров · 5 лет назад
This video covers the hardware and software for Newcastle University's Bioimaging Unit LSM800 confocal, including startup, shutdown, and operating the software. Details and bookmarks for sections below: Startup 00:16 - System Startup 01:52 - Using an Oil Immersion Objective 02:50 - Starting Zen and a quick overview 03:50 - Using the Oculars 04:13 - Using the camera to check your sample Basic channel Setup 05:00 - Setting up for confocal imaging with Smart Setup 07:15 - Describing Tracks and Channels and manual adjustment of Imaging Setup 08:00 - Line and Frame mode differences 09:03 - Detectors on System 09:35 - Fine tuning Imaging Setup manually 11:14- Going Live and using the histogram 11:54 - Using bidrectional scanning 12:15 - Using Nyquist sampling and changing frame size in Acquisition Mode 13:17 - Setting Gain and laser power using the histogram 14:18 - Setting Gain and laser power using the Range indicator 14:38 - 8 bit and 16 bit output 15:05 - Setting gain and laser on a 2 channel Track 15:38 - Taking a Snap Image 16:10 - checking the image for fine tuning 16:54 - Check focal planes for final image 17:34 - Checking for bleedthrough within a multichannel Track 18:40 - Improving Image Quality with dwell time 20:00 - Improving Image Quality with Averaging Zed Stacks 20:47 - Taking Zed Stacks using mark Centre 22:01 - zed sampling frequency 23:10 - Using Start Experiment 23:30 - Viewing 3D images 24:19 - Setting Zed Stack with First and Last Tiling and Multipositions 25:05 - Tiles and Positions setup 26:30 - Using confocal Zoom for overview 26:45 - Taking a Confocal TileScan 27:45 - Taking overview scans using Widefield Imaging 30:15 - Setting Multiple positions from an Overview Scan 31:19 - Checked zed positions for multiposition imaging with Verify Positions 32:14 - Navigating through multiposition czi ifiles 32:30 - Advanced Tiles setup for Preview Scans 34:22 - Setting Support Points for tiled images 36:09 - Focussing Strategy options Confocal and Airyscan imaging 37:38 - Using Confocal Zoom to take cropped images 38:30 - Nyquist confocal Imaging 38:54 - Using Smart Setup to create Airyscan setup 40:40 - comparing Airyscan to Confocal imaging 41:19 - checking Airyscan alignment Timelapse with Mulitpositions 41:50 - moving the stage via captured images to set up multipositional imaging 42:56 - Setting multiposition, multitime imaging 43:26 - Navigating through time series multiposition czi files 43:56 - Setting incubation conditions Saving and Shutting down 44:56 - Saving your images 45:46 - Shutting down Zen 46:02 - Copying data to server Hardware Shutdown 47:05 - Shutting down the hardware 47:22 - Cleaning oil immersion lenses after use