Sewer Inspection - 3693
Justin Jarquin
0:00 / 0:00
Sewer Inspection - 3693
29 просмотров · 13 дн. назад
Justin Jarquin
1 подписчик
29 просмотров · 13 дн. назад
Inspection Number: 431531-3693
Date: 10/5/2026 Time: 16:30
Technician: Ray Marin
Customer Name: Michael Von
Property Address: 3617 Corliss Avenue N, Seattle, WA 98103
Notes:
Measurements (##.# ft) refer to the video’s distance counter. Each segment begins at the farthest point, with negative readings as the camera withdraws. Each sewer line has two video segments.
Line 1: Accessed through the polyvinyl chloride (PVC) cleanout on the house’s left side. White/green PVC extended to the utility’s clay sewer main. The camera continued 70 feet along the main. Root intrusion was observed at the lateral-to-main connection; responsibility varies by jurisdiction.
Line 2: Accessed through the basement’s acrylonitrile butadiene styrene (ABS) cleanout. Black ABS extended 26.3 feet to the PVC lateral, which continued 14.5 feet to the utility’s main. No deficiencies were observed.
Recommendations
Contact the utility to confirm responsibility for the root intrusion. Recommend having a qualified plumber or utility personnel clear roots and repair as needed to maintain flow and prevent backups.